   POWER SUPPLY REQUIREMENTS (Optional package available)
         
               Extraction                                25 kV             7.5 mA
               Target                                      15 kV             15.0 mA
               Cesium Reservoir                    110 V                2.5  A
                Ionizer                                       18 V              36.0  A
                Reservoir Tube                        110 V                1.5  A
         
     
COMPONENTS
         
                 Model 120-A                  Sputter Source Head
                 Model 320                      Extraction Gap
                 Model 420                      Power Supply Package (OPTIONAL)

     
BEAM PERFORMANCE               
         
                 
Ion Species                         Beam Current (microamps)
     
                         H                                                    200
                         Li                                                        1
                         B                                                       80
                         C                                                     350
                         O                                                     200
                         Al                                                      10
                         Si                                                     400
                         P                                                        40
                         S                                                      100
                         Cl                                                     100
                         Fe                                                       20
                         Ni                                                       60
                         Cu                                                      60
                         Ag                                                    100
                         Cs                                                         1
                         Pt                                                      100
                        Au                                                      225