Specifications






















Positive Operation
         Total hydrogen beam                            1 mA
            H1+                                                   > 60%                                 
            H2 +                                                  < 20%
            H3 +                                                  < 20%
         Anode aperture diameter                     .25 mm
         Gas consumption                                 10 atm cc/hr
         Energy spread                                      20 eV
         Emittance                                               2 cm rad eV
         Filament lifetime                               100's of hours
         Other ions include                 He, N, C, O, Ar, Kr, I
                       
Negative Operation
To operate the source in a negative ion mode, it is necessary to offset the
intermediate electrode from the anode aperture. This results in the extraction of  ions from the periphery of the arc discharge which is rich in negative ions with a simultaneous reduction in electrons due to differences in diffusion and recombination coefficients.

         H-                                                        150 microamp
         Anode aperture diameter                        .6 mm
         Intermediate electrode offset                  1 mm
         Emittance                                               .6 cm rad eV
                           
Electrical Requirements (source head, only)
         Arc power supply                                   150 v dc 3 A
         Magnet power supply                             100 v dc 2 A
         Filament supply     (Filament Mesh)          5 v ac 30 A
                                        (Tungsten Wire)        10 v ac  50 A

Cooling Requirements
           Cooling                                                     3 gpm @ 20C
         
Mechanical
            Diameter                                                   6.0 in
            Height                                                       6.5 in
            Weight                                                     18.0 lbs